Vicflex flexible sprinkler fittings with uncompromising. Ul 1767 standard for earlysuppression fastresponse. Explanations on esfr sprinkler protection sprinkler age. Esfr type sprinklers definition advantages disadvantages comparison to conventional.
Jun 14, 2016 since the late 1980s, early suppression, fast response esfr sprinklers have been viewed as one of the greatest innovations in fire protection since henry parmelee first introduced the automatic sprinkler in 1874. Model esfr17 early suppression, fast response pendent. Early suppression, fast response upright sprinklers. The installation and material costs of these systems are more economical than the costs of creating and installing an inrack fire suppression system, often 30% to 50% less.
Shortly after the introduction of esfr sprinklers to the fire protection community, there was a great demand to use esfr sprinklers in 12. The concept is that fast response of sprinklers can produce an advantage in a fire if the response is accompanied by an effective discharge density that is, a sprinkler spray capable of fighting its way down through the fire plume in sufficient. Reliable sprinklers are available in a wide variety of finishes, temperature ratings, and styles. Model jl14 and jl17 esfr sprinklers datasheet fpc datacentre. Successful project management of an esfr sprinkler system j. In the most recent edition of nfpa, the 2010 edition, section 12. Around 1990 early suppression fast response esfr sprinkler systems began being installed in warehouses and distribution centers. In answering these questions, we will first look at types of systems that are used to protect warehouse occupancies. Nfpa allows less than 18 inches clearance from ceiling sprinklers when largescale fire tests for the particular hazard show less clearance is acceptable. Volume conventional sprinkler heads output rate 25 to 30 gallons per minute.
Discussion created by rbjorkman on feb 28, 2018 latest reply on sep 25. The model n25 is fm approved as a quick response storage sprinkler. Eliminate the use of inrack sprinklers when protecting highpiled storage of certain specified materials up to 40 ft. In the mid 1990s, fm global learned through fire testing that an obstruction as small as. Sprinkler centerline fire location clearance from ceiling to top of apparatus 1 baseline none none under one sprinkler 10 ft. May 04, 2017 esfr versus inrack sprinklers the current sprinkler system of choice is the esfr sprinkler system. Warehouse fire sprinkler codes and impact on storage racks. New inrack design criteria in nfpa and fm data sheet 89. Nfpa standard for the installation of sprinkler systems. Reduced freezeups means less impaired systems, displaced tenants, and repair work. Model esfr17 sprinklers are primarily used for ceilingonly sprinkler protec. Sprinklers operating in the remainder of the fire area also cool the ceilinglevel air temperatures while prewetting adjacent combustibles. New sprinklers of the same size, type and temperature rating must be installed.
Figure 2 and by fully engaging seating the wrench on the sprinkler wrench flats ref. Globe fire sprinkler remains open for business and focused on the health and safety of our employees while continuing our commitment to our customers. So, the required flow is 12x1581896 gpm so, can i choose a 2000 gpm pump. Since there have been no rdd data for rack storage with heights greater than. There is a good reason why only esfr sprinklers are referenced in the code. Prewetting adjacent combustibles helps to prevent the spread of fire beyond the fires origin. Prior to the design, layout, andor installation of any sprinkler system, please refer to vikings technical documentation and always consult with the ahj. Esfr sprinklers operate under the concept of getting large water droplets to the fire plume without being broken up on the fall from the sprinkler to the fire. Esfr early suppression fast response refers to both a concept and a type of sprinkler. The model esfr17 dry type sprinklers feature all of the same design criteria as 16.
Esfr early suppression, fast response ceiling mounted sprinklers can be used in warehouses in place of inrack fire sprinkler systems. High output conventional sprinkler heads output rate 60 gallons per minute. All listings applicable up to 40foot ceiling heights. Description viking early suppression fast response esfr pendent sprinkler vk503 is a fast. Viking vk500 esfr pendent sprinklers may be used in the protection of ordinary types of storage. Esfr high output, high volume systems are located in ceiling spaces as with conventional fire sprinkler systems. Do not clean sprinkler with soap and water, ammonia or any other cleaning fluid.
However, they are primarily intended to protect the following. Early suppression, fast response sprinklers sprinkler age. Pendent sprinkler mx8514 incorporates the capability to suppress. Model esfr17 early suppression, fast response upright sprinklers 16. Therefore if a business owner is moving into a building that is equipped with an esfr, and exposed expanded group a plastics is planned for rack storage, the k. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. These lists may not reference all models of oring sealed sprinklers. We are currently working on a large esfr warehouse project where a large number of electrical conduit banks run and chill water lines that create continuous nonsolid obstructions to the overhead esfr sprinklers and will require additional coverage below. Easy to retrofit into existing upright sprinkler systems can be installed on same branch line as k14 esfr pendent sprinklers protects up to 35 ft 10,7 m high buildings without using inrack sprinklers sprinklers may be spaced up to 12 ft 3,7 m for buildings up to 30 ft 9,1 m. The model jl17 esfr sprinkler is intended for installation in accordance with nfpa and fm loss prevention data sheets 20 and 89, as well as the authority having jurisdiction. Speed esfr sprinkler heads sense a fire and begin spraying water quicker than standard response sprinkler heads.
Minimax specific application early suppression fast response esfr. They are suppression mode sprinklers that are especially advantageous as a means of eliminating inrack sprinklers when protecting highpiled storage. Early suppression fast response esfr sprinkler product description the reliable model hl22 is an early suppression fast response esfr sprinkler with a nominal kfactor of 22. An introduction to early suppression fast response sprinklers.
Response esfr sprinkler is intended for use against severe fire challenges. Technical specification for model jl14 and jl17 esfr sprinklers. The visits resulted in multiple recommendations to either replace k14 esfr sprinklers with k17 esfr sprinklers or regulate storage heights to no greater than 15 ft 4. By examining spare sprinklers provided when systems were installed, the types of sprinklers used in a fire sprinkler system can be identified. Can an esfr sprinkler system keep you from getting soaked. But what are esfr sprinklers and what is their benefit. Esfr sprinklers solution to warehouse fire protection. If storage heights are larger than 25 feet, longitudinal flue spaces are required in addition to the transverse flues. For early suppression fast response esfr sprinklers, clearance between the sprinkler deflector and top of storage must be at least 36 inches. The sprinkler models and identification numbers specified herein may incorporate the use of an oring water seal. Early suppression fast response esfr sprinklers storage sprinkler u. Description viking early suppression fast response esfr upright sprinkler vk520 is a. You also want a solution that can meet your needs today and tomorrow, not one with a built in limit. Fm global no longer uses the term esfr however esfr sprinklers are viewed as simply k16.
Esfr provides protection that exceeds that of inrack systems. The design and installation of esfr sprinkler systems shall comply with the applicable standards of nfpa, nfpa231, nfpa 231c, fm loss prevention data 22, 821s, 729s and the authority having jurisdiction. How to calculate the flow requirement of an esfr system. Horizontal offset test number obstruction tip of joist to sprinkler centerline fire location clearance from ceiling to top of apparatus 1 baseline none none under one sprinkler 10 ft. Model jl14 and jl17 esfr sprinklers datasheet author. However, it was decided by parties other than myself they need to use esfr sprinklers. If there is a question as to whether a particular sprinkler model incorporates an oring water seal, please contact the sprinkler manufacturer or ul llc for assistance related to sprinkler identification. Vikings ul listed and fm approved dry esfr sprinklers combine the suppression benefits of an esfr with the advantages of a dry type sprinkler for cold.
Basically they have no rack storage, and the systems have been designed using standard heads with a k factor of 8. In buildings protected by properly designed and maintained fire sprinklers, over 99%. Model esfr 17 drytype sprinkler the tyco model esfr 17 drytype sprinkler is an easy to install, costeffective solution for boxinbox cold storage facilities. Esfr number of sprinklers in design area nfpa xchange. This sprinkler is designed to protect rack storage of various commodities and heights without the need for inrack sprinklers. Quick reference guide this guide is intended for general reference only. Dry type pendent sprinklers early suppression fast response 16. View and download viking esfr technical data manual online. In addition, the rack storage below is protected with 20mm sprinkler with a kfactor of 115 and a minimum head pressure of 1. Model esfr17 dry type sprinklers feature all of the same design criteria as 16.
Fm approved as a quickresponse, storage and nonstorage, sprinkler. Automatic sprinkler system basics international fog. Intermediate temperaturerated esfr pendent sprinklers, k25. That being said, you only calculate 12 esfr sprinklers that exhibit the highest demand. Esfr sprinkler performance is the ability of the sprinkler to provide large amounts of water, in a specific.
Nfpa standard for the installation of sprinkler systems provides specific details with respect to the use of special application sprinklers, such as esfr sprinklers and the commodities they are intended to protect. Fire administration national fire academy coffee break. Early suppression fast response sprinklers and obstructions. Early suppression fast response esfr systems viking.
In particular, the model esfr 17 upright sprinklers are designed to operate at substantially lowerend head pressures compared to esfr sprinklers with 14. Remove any sprinkler that has been painted other than factory applied model hl22 temperature ratings and approvals temperature classification temperature. This is found in the notes at the end of this table. The use of code requirements the following opening. Esfr fire suppression systems can be used in warehouses with ceilings as high as 45 feet and storage heights of 40 feet. I have chosen esfr 25 sprinklers for a warehouse, and i considered the number of activated sprinklers to be 12, and the min gpm of each sprinkler to be 158. The tyco model esfr 17 upright sprinklers are early suppression, fast response sprinklers having a nominal kfactor of 16. Based on nfpa, 2002 edition code in place at time of construction tables 12. Informal interpretations offer assistance on technical questions the informal interpretations featured in this post address nfpa, standard for the installation of sprinkler systems, early suppression fast response esfr sprinklers. The attached list a references wet type oring sealed sprinklers. Early suppression fast response esfr sprinkler protection. The model hl22 esfr sprinkler should be inspected and the sprinkler system maintained in accordance with nfpa 25. Stored palletized, solid piled, bin boxes, or shelf.
Esfr sprinkler comparison testing each of the 3 sprinklers tyco, viking, reliable were tested as follows 12 add tests total. The single interlock preaction sys tem piping network is supervised with a propylene glycol solution. The model jl17 esfr sprinkler is designed for ceiling only sprinkler system with no inrack sprinklers required. Jan 27, 2017 i am working on an existing spec warehouse built in 2004 using k14 esfr sprinklers designed at 75 psi.
Early suppression fast response esfr sprinklers are used to protect various occupancies according to the underwriters laboratory ul listing. Storage sprinklers storage sprinklers storage sprinklers are intended for use in specific. Therefore, structural elements to the building, hvac ducts, conduit, cable trays, and any other mechanical elements need to be placed in strategic locations to avoid obstructing the esfr. The reliable model hl22 is an early suppression fast. The model esfr 17 drytype sprinkler offers installation savings, less maintenance and less chance of damage compared to inrack sprinklers. Recent significant warehouse fires record storage nj. Increase sprinkler length within conditioned space, and move water further from freezing conditions. The kfactor for the esfr sprinkler can range from 11.
Spare sprinkler head storage cabinet installation select the correct spare sprinkler head cabinet in accordance with the automatic sprinkler systems handbook. The ceilingbased system became popular over 30 years ago because it could knock down and prevent a fire quickly in facilities with a ceiling 30 feet or lower. Many aspects of esfr sprinklers are unique compared to standard spray sprinklers. Improve safety and reduce headaches by eliminating frozen and burst pipes. Once operated, automatic sprinklers cannot be reassembled and reused. Esfr systems esfr sprinkler systems are designed to extinguish, as opposed to control, a fire.
When using this system for single, double and multiplerow rack storage, viking k25. Wrenchtighten the model esfr1 sprinkler using only the wtype 2 sprinkler wrench ref. The tyco model esfr1 pendent sprinklers are early suppression, fast response sprinklers having a nominal kfactor of 14. Transverse flues are the spaces between adjacent rack uprights or rack bays when looking sidetoside. We take great pride that globe solutions supply critical life safety applications and remain committed to supporting your construction needs during these challenging times. Important always refer to technical data sheet tfp700 for the installer warning that provides cautions with respect to handling and installation of sprinkler systems and components. Tyco model esfr25 pendent sprinklers are early suppression, fast response esfr sprinklers having a nominal kfactor of 25. The model esfr 25 early suppression fast response sprinkler as the building owner or engineering firm you want a fire protections solution that gives you options options on what you store and options on how things are stored. Since the late 1980s, early suppression, fast response esfr sprinklers have been viewed as one of the greatest innovations in fire protection since henry parmelee first introduced the automatic sprinkler in 1874. The roof level sprinklers are esfr 25mm with a kfactor of 360 and a minimum head pressure of 3. Model esfr17 dry type pendent sprinklers early suppression.
Esfr are suppression mode sprinklers capable of actual extinguishing the. This sprinkler is designed to respond quickly to growing fires with a high volume of water discharge to suppress rather than control fires. Model n25 esfr sprinkler specification sprinklers shall be early suppression fast response. Tyco model esfr1 pendent sprinklers are early suppression, fast response esfr sprinklers having a nominal kfactor of 14. View and download tyco esfr 1 general description online. The tyco model esfr 25 pendent sprinklers are listed by ul for specific applications with a ceiling height greater than 45 ft. Esfr sprinklers the perfect solution to warehousing updated. Reliable sprinklers have been designed and assembled in the united states since 1920 and are suitable to protect a wide range of applications, including commercial, residential, storage, and special applications. Esfr technology a relatively new sprinkler technology is changing that.
Since nfpa, standard for the installation of sprinkler systems, indicates that you do not need inrack sprinklers if you have. Beyond the above restrictions, esfr obstructions are the achilles heel of esfr sprinklers systems. A cabinet of replacement sprinklers should be provided for this purpose. Model esfr 1 sprinklers are primarily designed for protection of the following. The added benefit to the use of this technology is in most cases, the requirement for rack sprinklers can be circumvented. After installation, inspect the link assembly of each model esfr1 sprinkler for damage. Fhc project examples hydraulic calculation examples. The sprinkler is designed to respond quickly to a growing fire and deliver a heavy discharge of water to suppress the fire. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. As per the 1989 edition the correct number of spare sprinkler is as follows.
An esfr sprinkler system is located in the ceiling structure yet for many categories of product offers fire protection better than inrack systems. For csma and esfr sprinklers, the additional sprinklers included in the design area for obstructions do not. Model hl22 esfr sprinkler datasheet fpc datacentre. The use of early suppression fast response esfr sprinkler systems is becoming more prevalent in the protection of warehouse storage occupancies. They are suppressionmode sprinklers that are especially advantageous as a means of eliminating the use of inrack sprinklers when protecting highpiled storage. Early suppression fast response esfr sprinklers storage sprinklers esfr sprinklers vk504 esfr dry pendent k242 16.
Preprimed single interlock preaction cold storage system. Technical specification for model jl14 and jl17 esfr sprinklers created date. Changing trends in rack systems demand a closer look at. Viking early suppression fast response esfr pendent sprinkler vk500 is a fast response fusible element type sprinkler designed for early fire suppression. Early suppression fast response esfr sprinklers were developed to meet the demands of high challenge storage fire scenarios and are a common choice to protect warehouses. The tyco model esfr 17 pendent sprinklers are early suppression, fast response sprinklers having a nominal kfactor of 16.
700 1185 986 1094 948 1502 386 1225 189 530 1450 207 282 1628 140 8 1266 455 1409 1072 916 929 270 1244 1111 731 199 1325 1016 1086 1136